Violation Detail
Standard Cited: 5A0001 OSH Act General Duty Paragraph
Inspection Nr: 107658403
Citation: 01002
Citation Type: Serious
Abatement Status: I
Initial Penalty:
Current Penalty:
Issuance Date: 04/24/1995
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 04/27/1995
Gravity: 01
Report ID: 0214200
Contest Date:
Final Order:
Related Event Code (REC):
Emphasis:
Text For Citation: 01 Item/Group: 002 Hazard: LOCKOUT
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: %% Employee(s) were exposed to the hazard of physical contact with the rotating parts and material and being unable to stop the machine. 1)Maintenance Area - Adjacent to Welding Shop - Rigid 300 #1206, I.D.#A253402- 2355, a portable power drive pipe threading machine was not provided with a constant pressure foot treadle control switch. Among other methods one feasible and acceptable abatement method to correct this hazard is to: 1. Provide a constant pressure foot treadle control switch. Reference Publication: ANSI/AMSE B208.1 - 1982, Section 4.4tion