Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

Inspection Nr: 107232134

Citation: 01002

Citation Type: Serious

Abatement Status: X

Initial Penalty: $2,500.00

Current Penalty: $1,250.00

Issuance Date: 03/15/1994

Nr Instances: 1

Nr Exposed: 1

Abatement Date: 12/30/1994

Gravity: 10

Report ID: 1032500

Contest Date:

Final Order:

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 04/06/1994 $1,250.00 12/30/1994 Serious  
Penalty Z: Issued 03/15/1994 $2,500.00 03/21/1994 Serious  

Text For Citation: 01 Item/Group: 002 Hazard: FALLING

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential injuries from elevator collapse: (a)Freight elevator was not installed in accordance with American National Standard Safety Code for Elevators (ANSI A 17.11971) NOTE: See appropriate rule noted below: 1.Chain was used to for suspension of elevator car in lieu of steel wire rope. See Rule 212.1. 2.A single chain was used to hoist car. The minimum number of wire ropes shall not be less than two (NOTE: Minimum diameter shall be onehalf inch). See Rule 212.4. 3.Safety devices to prevent free fall were not installed. Safeties shall consist of a device which applies pressure to steel guide rails and activated based upon a set governor speed. See Rule 205.1 and 205.5. 4.Elevator shaft was not equipped with steel guide rails. See Rule 203.2. 5.Elevator car was not enclosed. Car sides and top was enclosed with chain link fencing material. See Rule 204.1a. 6.Elevator car was not equipped with car doors. And landing gate at the first floor was not equipped with a functioning electrical contact. See Rule 204.4. 7.Car capacity was not posted. See Rule 301.10 and 207. 8.Switches are not fail safe. Single switches are used to control interlocked door/gate. In case of failure of door or gate switch the car could start or run. See Rule 306.9c. NOTE: This is not a conclusive list of the deficiencies for this elevator. Among other methods, one feasible and acceptable abatement method to correct this hazard is:HAZARD IS: 1.Replace elevator in accordance with current ANSI A17.1 series, or 2.Remove elevator from service.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close