Violation Detail
Standard Cited: 19260706 A03 Requirements for masonry construction.
Inspection Nr: 1062492.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $2,800.00
Current Penalty: $2,800.00
Issuance Date: 05/21/2015
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0215000
Contest Date:
Final Order: 06/17/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 05/21/2015 | $2,800.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.706(a)(3): The limited access zone for masonry construction was not established on the side of the wall which was un-scaffolded: LOCATIONS: 579 VanBuren Street, Brooklyn, NY, West end of project. On or about January 15, 2015. A). Employees working to backfill the foundation and excavation were exposed to potential struck by and caught in hazards because there was no limited access zone around the 6 foot tall masonry block wall being erected at the west side of the project.