Violation Detail
Standard Cited: 19100023 C01 Ladders.
Inspection Nr: 1048086.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,400.00
Current Penalty: $2,200.00
Issuance Date: 09/09/2015
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 5
Report ID: 0418500
Contest Date:
Final Order: 10/06/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/06/2015 | $2,200.00 | Serious | ||
Penalty | Z: Issued | 09/09/2015 | $4,400.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. a) Southeast end of the Plant: An employee working on top of the conveyor belt on the APBS #2 machine was exposed to falls of up to 8 feet, 4 inches and he was not protected from falls by guard rails or other proper means. ABATEMENT CERTIFICATION IS REQUIRED.