Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1047617.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,500.00
Current Penalty: $2,250.00
Issuance Date: 06/18/2015
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 07/03/2015
Gravity: 5
Report ID: 0522300
Contest Date: 07/09/2015
Final Order: 11/16/2015
Related Event Code (REC):
Emphasis:
Substance: 8870
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 11/16/2015 | $2,250.00 | 07/03/2015 | Serious | |
Penalty | C: Contested | 07/13/2015 | $4,500.00 | 07/03/2015 | Serious | |
Penalty | Z: Issued | 06/18/2015 | $4,500.00 | 07/03/2015 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On or about March 19, 2015, the employer failed to ensure employees performing maintenance on the Mazak CNC machines applied a lock to ensure the machine is not energized.