Violation Detail
Standard Cited: 19261052 C12 Stairways.
Inspection Nr: 1034469.015
Citation: 01002
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $4,900.00
Current Penalty: $4,410.00
Issuance Date: 05/13/2015
Nr Instances: 2
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0418800
Contest Date:
Final Order: 06/01/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/01/2015 | $4,410.00 | Serious | ||
Penalty | Z: Issued | 05/13/2015 | $4,900.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: a. On or about February 05, 2015, at 8420 and 8430 NW 33rd Terrace, employees were using a stairway landing to access the roof deck of a new residential building, for the purpose of installing drywall, and for which the stairway landing did not have a guardrail system.