Powered by GoogleTranslate

Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

This violation item has been deleted.

Inspection Nr: 103042628

Citation: 01002

Citation Type: Willful

Abatement Status: X

Initial Penalty: $10,000.00

Current Penalty: $10,000.00

Issuance Date: 10/31/1990

Nr Instances: 1

Nr Exposed: 10

Abatement Date: 11/30/1990

Gravity: 10

Report ID: 0522500

Contest Date: 11/20/1990

Final Order: 09/27/1991

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty F: Formal Settlement 09/27/1991 $10,000.00 11/30/1990 Willful  
Penalty Z: Issued 10/31/1990 $10,000.00 11/30/1990 Willful  

Text For Citation: 01 Item/Group: 002 Hazard: STRUCK BY

SECTION 5(A)(1) OF THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970: THE %% EMPLOYER DID NOT FURNISH EMPLOYMENT AND A PLACE OF EMPLOYMENT WHICH WERE FREE FROM RECOGNIZED HAZARDS THAT WERE CAUSING OR LIKELY TO CAUSE DEATH OR SERIOUS PHYSICAL HARM TO EMPLOYEES IN THAT EMPLOYEES WERE EXPOSED TO: A) WORKERS WERE EXPOSED TO THE HAZARDS OF BUILDING COLLAPSE. THE EMPLOYER IS IN VIOLATION OF RECOGNIZED PRINCIPLES AND PRACTICES OF STEEL ERECTION AND OF THE AMERICAN NATIONAL STANARD FOR CONSTRUCTION AND DEMOLITION OPERATIONS-STEEL ERECTION SAFETY REQUIREMENT, ANSI A10.13-1989, PRAGRAPH 11.1 (SECOND SENTENCE), WHICH READS: "THE SEQUENCE OF ERECTION, BOLTING, TEMPORARY GUYING, RIVETING AND WELDING SHALL BE SUCH AS TO MAINTAIN THE STABILITY OF THE STRUCTURE FORM AT ALL TIMES DURING THE CONSTRUCTION. CONSIDERATION SHALL BE GIVEN TO THE DEAD WEIGHT OF THE STRUCTURE, WEIGHT, AND WORKING REACTIONS OF ALL CONSTRUCTION EQUIPMENT PLACED THEREON AND ALL EXTERNAL FORCES THAT MAY BE APPLIED." THE HAZARDS OF THE COLLAPSE CAN BE ABATED BY A PROGRAM INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING FACTORS: 1) PLUMB THE COLUMNS OF THE BUILDING. 2) CONNECT THE BEAMS TO THE COLUMNS. 3) USING DIAGONAL GUYING, WHICH IS ATTACHED BETWEEN THE COLUMN AND A BEAM TO BE LEVELED, DO THE FOLLOWING: A) LOOSEN THE CONNECTION BOLTS, IF NEEDED. B) POSTION THE BEAM SO THAT IT IS ALIGNED WITH THE BOLT HOLES AND IN A HORIZONTAL POSITION. C) PLACE FULL-SIZED BOLTS THROUGH THE FLANGE ATTACHMENT HOLES. 4) CHECK THAT COLUMN/BEAM MEETS ERECTION SPECIFICATIONS. 5) REMOVE DIAGONAL BRACING.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.