Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1020177.015
Citation: 01002
Citation Type: Serious
Abatement Date: 04/01/2015 2
Initial Penalty: $5,100.00
Current Penalty: $3,060.00
Issuance Date: 03/17/2015
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0419400
Contest Date:
Final Order: 04/02/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/02/2015 | $3,060.00 | 04/01/2015 | Serious | |
Penalty | Z: Issued | 03/17/2015 | $5,100.00 | 04/01/2015 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy (a) New Press #2 Furnace - On or about January 22, 2015 there were no specific energy control procedures for this machine.