Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1015659.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $2,800.00
Current Penalty: $2,800.00
Issuance Date: 01/07/2015
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0214500
Contest Date:
Final Order: 03/04/2015
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 01/07/2015 | $2,800.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Pump Jack Scaffolding at Exterior Building Front: Employees engaged in removal of siding and gutters, were using an aluminum extension ladder extended to 16 feet above the ground surface to access the scaffold's work platform and the side rails did not extend at least 3 feet above the upper landing of the scaffold, on or about 12/29/14.