Violation Detail
Standard Cited: 19100107 G02 Spray finishing using flammable and combustible materials.
Inspection Nr: 915140.015
Citation: 01001E
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,500.00
Current Penalty: $0.00
Issuance Date: 07/30/2013
Nr Instances: 2
Nr Exposed: 1
Abatement Date: 08/23/2013
Gravity: 5
Report ID: 0213900
Contest Date:
Final Order: 08/26/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/26/2013 | $0.00 | 08/23/2013 | Serious | |
| Penalty | Z: Issued | 07/30/2013 | $3,500.00 | 08/23/2013 | Serious |
Text For Citation: 01 Item/Group: 001E Hazard:
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: a) Flammable wash spray booth - EXXSOL D60 Fluid, a class III combustible solvent (dearomatized hydrocarbons) that was sprayed in the booth was allowed to accumulate on the absorbent mats lining the floor of the booth. On or about 6/27/13. b) Flammable paint spray booth - Overspray residue from class 1B ad 1C flammable paints such as, but not limited to PPG Industries Safety Orange 2.08 VOC Ultra (heptan-2-one), PPG Industries Multiprime EFD Inhibitive Primer (xylene, toluene, ethylbenzene), and PPG Industries97-725 (xylene, toluene, 2-(propyloxy)ethanol) was allowed to accumulate on the walls of the booth and on other objects stored in the booth. On or about 6/27/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19
Translate