Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1472332.015
Citation: 01001E
Citation Type: Serious
Abatement Date: 10/15/2020 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/18/2020
Nr Instances: 1
Nr Exposed: 441
Related Event Code (REC): P
Gravity: 10
Report ID: 0215000
Contest Date: 10/20/2020
Final Order: 08/05/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/05/2022 | $0.00 | 10/15/2020 | Serious | |
Penalty | C: Contested | 12/14/2020 | $0.00 | 10/15/2020 | Serious | |
Penalty | Z: Issued | 09/18/2020 | $0.00 | 10/15/2020 | Serious |
Text For Citation: 01 Item/Group: 001E Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): Location: 120 West 106th Street New York NY 10025 On or about: March 18 2020 and thereafter. a) Employees were required to wear N95 Respirators while providing medical treatment to COVID 19 positive patients. A Licensed Practical Nurse had failed the fit test because she identified the agent being used. She was told she failed but was provided and instructed to use the N95 Respirator.