Violation Detail
Standard Cited: 19100147 D05 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 901753.015
Citation: 01001D
Citation Type: Serious
Abatement Date: 11/27/2013
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/11/2013
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC): A
Gravity: 10
Report ID: 0626700
Contest Date:
Final Order: 11/04/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/04/2013 | $0.00 | 11/27/2013 | Serious | |
Penalty | Z: Issued | 10/11/2013 | $0.00 | 11/27/2013 | Serious |
Text For Citation: 01 Item/Group: 001D Hazard:
29 CFR 1910.147(d)(5)(i): The employer did not ensure that all potentially hazardous stored or residual energy was relieved, disconnected, restrained, and otherwise rendered safe. On April 17, 2013 or at times prior thereto at E-1 exchangers, in the Catalytic Hydrodesulfizer Unit 2 (CHD-2) at the ExxonMobil Beaumont Refinery the employer did not ensure that procedures utilized to de-inventory, and neutralize the equipment during turnaround were complete and effective to control the unexpected release of residual energy.