Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1739037.015
Citation: 01001D
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/19/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 09/17/2024
Gravity: 1
Report ID: 0830600
Contest Date:
Final Order: 09/13/2024
Related Event Code (REC):
Emphasis:
Substance: 9000
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 08/19/2024 | $0.00 | 09/17/2024 | Serious |
Text For Citation: 01 Item/Group: 001D Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a.) On or about April 4, 2024, and at times prior, the employer did not provide fit tests for employees who were required to wear Moldex half-face respirators or 3M N-95s in the workplace. Employees in the stone cutting area were observed wearing N-95s and half-face respirator; there were no fit tests completed, exposing employees to silica inhalation hazards. Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Translate