Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1726578.015
Citation: 01001D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/12/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 04/26/2024
Gravity: 5
Report ID: 0523300
Contest Date:
Final Order: 05/03/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/03/2024 | $0.00 | 04/26/2024 | Serious | |
Penalty | Z: Issued | 04/12/2024 | $0.00 | 04/26/2024 | Serious |
Text For Citation: 01 Item/Group: 001D Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6). a) On or about and at times prior to March 20, 2024, at the previously addressed inspection site, employees servicing the Accurpress 710010 #16 press brake were exposed to machine hazards and associated moving parts because applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.