Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1571418.015
Citation: 01001D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/07/2022
Nr Instances: 3
Nr Exposed: 3
Abatement Date: 05/27/2022
Gravity: 10
Report ID: 0524500
Contest Date:
Final Order: 05/19/2022
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/19/2022 | $0.00 | 05/27/2022 | Serious | |
| Penalty | Z: Issued | 04/07/2022 | $0.00 | 05/27/2022 | Serious |
Text For Citation: 01 Item/Group: 001D Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): - L&N Industries, Inc. Located at 2250 Ray Rd. Rushville, IL 62681 a) On or about January 6, 2022, the employer requires the use of a respirator when using compressed air to clean filters and did not require employees to be fit tested prior to use. b) On or about January 6, 2022, the employer requires the use of a respirator when working in the wet paint booth and did not require employees to be fit tested prior to use. c) On or about January 6, 2022, the employer requires the use of a respirator when working in the powder coating area and and did not require employees to be fit tested prior to use
Translate