Violation Detail
Standard Cited: 19100147 C04 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1518735.015
Citation: 01001D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/11/2021
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 06/28/2021
Gravity: 10
Report ID: 0418400
Contest Date:
Final Order: 06/09/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/09/2021 | $0.00 | 06/28/2021 | Serious | |
| Penalty | Z: Issued | 05/11/2021 | $0.00 | 06/28/2021 | Serious |
Text For Citation: 01 Item/Group: 001D Hazard:
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control a) At the site in the trim and drill area, on or about March 10, 2021, the employer did not develop lockout tagout procedures for a cable system used to open and close the robot door, exposing employees to amputation hazards.