Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1472977.015
Citation: 01001D
Citation Type: Serious
Abatement Date: 09/25/2020 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/15/2020
Nr Instances: 1
Nr Exposed: 7
Related Event Code (REC): P
Gravity: 10
Report ID: 0215000
Contest Date: 10/12/2020
Final Order: 03/10/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/10/2021 | $0.00 | 09/25/2020 | Serious | |
Penalty | C: Contested | 01/06/2021 | $0.00 | 09/25/2020 | Serious | |
Penalty | Z: Issued | 09/15/2020 | $0.00 | 09/25/2020 | Serious |
Text For Citation: 01 Item/Group: 001D Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test. Site: 2749 Linden Blvd Brooklyn, NY On and after 3/15/20 a) The employer provided respirators labeled KN95 to employees to wear as personal protective equipment when performing patient care for suspected or confirmed Covid-19 patients. Employee's not fit tested prior to initial use.