Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1407421.015
Citation: 01001D
Citation Type: Serious
Abatement Date: 09/06/2019 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/08/2019
Nr Instances: 3
Nr Exposed: 10
Related Event Code (REC): A
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 08/22/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/22/2019 | $0.00 | 09/06/2019 | Serious | |
Penalty | Z: Issued | 08/08/2019 | $0.00 | 09/06/2019 | Serious |
Text For Citation: 01 Item/Group: 001D Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Building 1, Moulder W90-LMC-Leadermac Platinum 523; On or about May 30, 2019 lockout or tagout devices were not affixed to each energy isolating device by authorized employee(s) while an employee was working inside of the moulder performing setup tasks. (b) Building 1, Moulder W90-LMC-Leadermac Platinum 523; Lockout or tagout devices were not affixed to each energy isolating device by authorized employee(s) while an employee was working inside of the moulder performing setup tasks. (c) Building 1, Moulder W9-Leadermac-C230-6; Lockout or tagout devices were not affixed to each energy isolating device by authorized employee(s) while an employee was working inside of the moulder performing setup tasks.