Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 1388500.015
Citation: 01001D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/26/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 09/23/2019
Gravity: 10
Report ID: 0317500
Contest Date:
Final Order: 08/12/2019
Related Event Code (REC): R
Emphasis:
Substance: 1840
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/12/2019 | $0.00 | 09/23/2019 | Serious | |
Penalty | Z: Issued | 07/26/2019 | $0.00 | 08/07/2019 | Serious |
Text For Citation: 01 Item/Group: 001D Hazard:
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a) In the T-1 Shop, on or about May 1, 2019 - The employer failed to fit test a Burner who is required to wear a respirator because the Burner was overexposed to nickel, metal and insoluble compounds (as Ni) above the permissible exposure limit prior to his initial use of a tight-fitting half mask air purifying respirator.