Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1276870.015
Citation: 01001D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,467.00
Current Penalty: $0.00
Issuance Date: 04/04/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 04/30/2018
Gravity: 5
Report ID: 0524200
Contest Date: 04/27/2018
Final Order: 08/13/2018
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 08/13/2018 | $0.00 | 04/30/2018 | Serious | |
| Penalty | C: Contested | 05/07/2018 | $6,467.00 | 04/30/2018 | Serious | |
| Penalty | Z: Issued | 04/04/2018 | $6,467.00 | 04/30/2018 | Serious |
Text For Citation: 01 Item/Group: 001D Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: a) Machine Shop - On or about November 6, 2017, the employer did not ensure an employee performing the servicing and maintenance task of filing debris from the chuck jaws of the Mori-Seiki Lathe Machine, model #SL-25B, serial #3775, was trained as an Authorized employee to acquire the knowledge and skills needed for the safe application, usage, and removal of the energy controls.