Violation Detail
Standard Cited: 19260452 I07 Additional requirements applicable to specific types of scaffolds.
Inspection Nr: 1250184.015
Citation: 01001D
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/20/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 10/26/2017
Gravity:
Report ID: 0830600
Contest Date:
Final Order: 11/02/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/02/2017 | $0.00 | 10/26/2017 | Other | |
| Penalty | Z: Issued | 10/20/2017 | $0.00 | 10/26/2017 | Serious |
Text For Citation: 01 Item/Group: 001D Hazard:
29 CFR 1926.452(i)(7): Platform units were not nailed, bolted, or otherwise secured to outriggers to prevent their displacement: a) On or about July 27, 2017 and at times prior, Quest Masonry, Inc., as the creating and correcting employer, did not ensure that the planks were nailed, bolted, or secured to the outriggers to prevent their displacement. A foreman of Quest Masonry Inc. and Funez Stucco LLC were working on each end of the outer planks when one of the workers moved towards the other worker. The planks tilted to one side which caused both workers to fall approximately 40 feet to the ground.