Violation Detail
Standard Cited: 19100107 E02 Spray finishing using flammable and combustible materials.
Inspection Nr: 915140.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,500.00
Current Penalty: $0.00
Issuance Date: 07/30/2013
Nr Instances: 2
Nr Exposed: 3
Abatement Date: 08/23/2013
Gravity: 5
Report ID: 0213900
Contest Date:
Final Order: 08/26/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/26/2013 | $0.00 | 08/23/2013 | Serious | |
| Penalty | Z: Issued | 07/30/2013 | $3,500.00 | 08/23/2013 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations were not at a minimum required for operations or they exceeded a supply for one day or one shift: a) Flammable wash booth - Combustible chemicals such as, but not limited to a 55 gallon drum and a five gallon bucket containing EXXSOL D60 Fluid, a class III combustible solvent (dearomatized hydrocarbons) were stored and used in the booth. Both exceeded the amount used in one day. On or about 6/27/13. b) Flammable paint booth - Chemical including, but not limited to 6 five gallon containers of acetone (flammable class 1B), two partially full containers of acetone connected to a parts washer, and several one gallon containers of other flammable chemicals such as thinners (flammable class 1B) were stored and used in the booth. Each of these exceeded the amount used in one day. On or about 6/27/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Translate