Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1794916.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/08/2025
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/26/2025
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 06/03/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/03/2025 | $0.00 | 06/26/2025 | Serious | |
Penalty | Z: Issued | 05/08/2025 | $0.00 | 06/26/2025 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. On or about December 13, 2024, the employer engaged in spot check walk ins to review, among other things, the general process for hazardous energy control (LOTO). However, as part of an ongoing update, the periodic inspections for the hazardous energy control (LOTO) procedures for the Pot-Mixer-Mepaco-02 machine, Model 170, Serial number 462, in the retort area, had not yet been completed and updated to identify and correct any inadequacies in the procedure.