Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 1785592.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/21/2025
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 06/27/2025
Gravity: 1
Report ID: 0215600
Contest Date:
Final Order: 05/27/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/27/2025 | $0.00 | 06/27/2025 | Serious | |
| Penalty | Z: Issued | 04/21/2025 | $0.00 | 06/06/2025 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting respirator is fit tested prior to initial use, whenever a different respirator facepiece (size, style, make or model) is used, and at least annually thereafter. Euro Plus GC Corp: 48-04 (48-00) Astoria Blvd. South, Astoria, NY. a) The employer provided and required employees to wear tight-fitting 3M half-mask elastomeric respirators with gas/vapor cartridges/filters P100 and 3M 8511 N95 respirators while engaged in manufacturing activities including cutting, polishing, and sanding marble and quartzite stone containing 40 to 90% crystalline silica. The employer did not provide fit testing to employees prior to required use of respirators; on or about 10/31/2024. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.