Violation Detail
Standard Cited: 19100147 C04 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1753707.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $0.00
Issuance Date: 12/04/2024
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 01/31/2025
Gravity: 10
Report ID: 0625500
Contest Date:
Final Order: 12/26/2024
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/26/2024 | $0.00 | 01/31/2025 | Serious | |
Penalty | Z: Issued | 12/04/2024 | $16,131.00 | 12/24/2024 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control At the ring remover: On or about June 07, 2024, and at times prior thereto, employees were required to perform maintenance tasks on the Ring Remover CR2450 without outlining specific procedures for testing and verifying that the machine was de-energized.