Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 1723391.015
Citation: 01001C
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/16/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0627100
Contest Date: 08/07/2024
Final Order: 02/24/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/24/2025 | $0.00 | Other | ||
Penalty | C: Contested | 08/15/2024 | $0.00 | Serious | ||
Penalty | Z: Issued | 07/16/2024 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: On or about January 25, 2024, in the machine shop, employees welding on stainless steel parts were provided and required to wear 3M 6200 half-face respirators with NIOSH 6001 organic vapor cartridges. Employees had not been fit-tested.