Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1721997.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $0.00
Issuance Date: 07/12/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/28/2024
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 08/05/2024
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/05/2024 | $0.00 | 08/28/2024 | Serious | |
Penalty | Z: Issued | 07/12/2024 | $16,131.00 | 08/28/2024 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. (a) On or about January 30, 2024, the employer did not perform an annual inspection of the Machine Specific Lockout/Tagout for Truck Maintenance procedure and review each employee's responsibilities under the procedure to ensure employees were correctly implementing energy control procedures when performing maintenance on waste collection vehicles in the maintenance department, exposing employees to entanglement hazards.