Violation Detail
Standard Cited: 19260251 E08 IV Rigging equipment for material handling.
Inspection Nr: 1709815.015
Citation: 01001C
Citation Type: Serious
Abatement Date: 06/06/2024
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/10/2024
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): R
Gravity: 5
Report ID: 0216000
Contest Date: 05/31/2024
Final Order:
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 02/14/2025 | $0.00 | 06/06/2024 | Serious | |
Penalty | Z: Issued | 05/10/2024 | $0.00 | 06/06/2024 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1926.251(e)(8)(iv): Synthetic web slings with broken or worn stitches were not immediately removed from service. On or about: November 11, 2023 Location: 16 Wade Sq., Bronx, NY 10457 a) Exterior wall panel lifted by two nylon slings, Lift-All brand EE2-804D. One of the nylon straps had observable damage and fraying of the material. Sling was not removed from service.