Violation Detail
Standard Cited: 19101025 E02 Lead.
Inspection Nr: 1700977.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/23/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 02/26/2024
Gravity: 5
Report ID: 0317500
Contest Date:
Final Order: 02/09/2024
Related Event Code (REC): C
Emphasis:
Substance: 1591
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/09/2024 | $0.00 | 02/26/2024 | Serious | |
Penalty | Z: Issued | 01/23/2024 | $0.00 | 02/26/2024 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.1025(e)(2): Respiratory protection was not provided to supplement engineering and work practice controls that did not control employee's exposure to or below 50 micrograms per meter cubed: a) In the Welding and Fab Shop, on or about October 17, 2023 - A Machine Operator was not provided with respiratory protection to supplement the down draft table and dust collector that were used while cutting with the Bodor Laser. The engineering controls did not control the Machine Operator's exposure to lead to or below 50 micrograms per meter cubed while cutting stainless steel with the Bodor Laser which resuspended previously settled particulate containing lead from cutting honeycombs coated with tin lead solder on the Bodor Laser.