Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1631156.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,278.00
Current Penalty: $0.00
Issuance Date: 04/27/2023
Nr Instances: 1
Nr Exposed: 45
Abatement Date: 03/04/2024
Gravity: 5
Report ID: 0627100
Contest Date: 05/17/2023
Final Order: 05/13/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/13/2024 | $0.00 | 03/04/2024 | Serious | |
Penalty | C: Contested | 05/17/2023 | $12,278.00 | 05/23/2023 | Serious | |
Penalty | Z: Issued | 04/27/2023 | $12,278.00 | 05/23/2023 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about October 27, 2022, in the planer #1 area, employees performed servicing and maintenance such as, but not limited greasing the chain sprocket. Lockout procedures for equipment such as, but not limited to planer #1 had not been inspected annually.