Violation Detail
Standard Cited: 19100147 C05 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1606228.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/28/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/25/2023
Gravity: 5
Report ID: 0336000
Contest Date:
Final Order: 01/18/2023
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/18/2023 | $0.00 | 01/25/2023 | Serious | |
| Penalty | Z: Issued | 12/28/2022 | $0.00 | 01/25/2023 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s). a.) Tonnard Manufacturing Corporation, Bay 3 press area, on or about 07/06/2022 and times prior thereto: Employees that periodically conduct servicing maintenance and repairs to equipment were provided with Red locks to use for Lockout Tagout/Energy Control purposes. A Red lock, which was applied to disconnect #69 on the Niagara 4 1/2 ton press machine #177, did not indicate the identity of the employee who applied the device.