Violation Detail
Standard Cited: 19100147 E01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1556845.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/11/2022
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 02/24/2022
Gravity: 10
Report ID: 0111700
Contest Date:
Final Order: 03/07/2022
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/07/2022 | $0.00 | 02/24/2022 | Serious | |
Penalty | Z: Issued | 02/11/2022 | $0.00 | 02/24/2022 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(e)(1): Before lockout tagout devices were removed, the work area was not inspected to ensure that nonessential items had been removed or ensured that machine or equipment components were operationally intact. Split Steel Cell, OJIM splitter machine SP-011 - On or about October 5, 2021, the work area was not inspected by maintenance employees to ensure that the machine or equipment components were operationally intact. A wooden block used by maintenance employees as an energy isolating device was not removed from the machine prior to removal of the lockout devices and giving control of the machine to the operator.