Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1527370.015
Citation: 01001C
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/24/2021
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 10/21/2021
Gravity: 5
Report ID: 0418300
Contest Date:
Final Order: 10/19/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/19/2021 | $0.00 | 10/21/2021 | Other | |
| Penalty | Z: Issued | 09/24/2021 | $0.00 | 10/21/2021 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: (a) On or about 04/17/2021 - Strapper #5 at Line #1 in the #2 position, employees were exposed to caught-in hazards when performing periodic maintenance activities such as, but not limited to, oiling and/or wiping the chain in the Timing Belt Table Drive unit with a hand-held rag and the machine had not been shut down as required in the written lockout/tagout procedure number 80 for the Auto Strappers.