Violation Detail
Standard Cited: 19100147 C04 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1504956.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/05/2021
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 06/07/2021
Gravity: 5
Report ID: 0522500
Contest Date:
Final Order: 05/26/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/26/2021 | $0.00 | 06/07/2021 | Serious | |
| Penalty | Z: Issued | 05/05/2021 | $0.00 | 05/25/2021 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: 29 CFR 1910.147(c)(4)(ii)(D): Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures. a. On or about April 20, 2021, and at times prior, the energy control procedures associated with the ASRS, Compactors, Large Pack Line, and Packaging Line did not clearly and specifically outline verification of the effectiveness of the energy control measures taken. As a result, employees were exposed to electrical, gravitational, and pneumatic energy while performing servicing and maintenance activities.