Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1492580.015
Citation: 01001C
Citation Type: Serious
Abatement Date: 03/10/2021 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/11/2021
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 1032500
Contest Date:
Final Order: 03/01/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/01/2021 | $0.00 | 03/10/2021 | Serious | |
Penalty | Z: Issued | 02/11/2021 | $0.00 | 03/10/2021 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) Milk Barn Basement: On September 15, 2020, the employer exposed employees repairing and maintaining a teat spray block attached to the Waikato Rotary Parlor deck to potential hazardous energies. An exposed worker had not received training on when and how to control hazardous energy. NOTE: Abatement certification AND documentation are required for this item.