Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1478392.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,940.00
Current Penalty: $0.00
Issuance Date: 07/20/2020
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 08/13/2020
Gravity: 5
Report ID: 0729700
Contest Date:
Final Order: 08/11/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/11/2020 | $0.00 | 08/13/2020 | Serious | |
Penalty | Z: Issued | 07/20/2020 | $6,940.00 | 08/13/2020 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: At 3738 S. Norman St, Wichita, KS, the employer failed to conduct an annual or more frequent inspection of the energy control procedure and to ensure those employees had the knowledge[and skills for the safe application, usage, and removal of energy controls on all equipment used at facility in the following instances: 1) Big Mac Dust Collector P.D. Pump Model and S/N Unknown 2) Blum Hinger Minipress Model and S/N Unknown 3) Flat Line Oven Model and S/N Unknown 4) !/2" Dado Table Saw Model and S/N Unknown