Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1425266.015
Citation: 01001C
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $9,446.00
Current Penalty: $0.00
Issuance Date: 02/18/2020
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0134000
Contest Date:
Final Order: 03/10/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/10/2020 | $0.00 | Serious | ||
Penalty | Z: Issued | 02/18/2020 | $9,446.00 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: Fabrication shop, 15 Linwood Street, Somerville, MA a) On or about August 22, 2019, an employee was exposed to the release of hazardous energy from a press brake that was not locked out during a change of dies. Employees were not trained on the purpose of the energy control program, or hazards associated with lockout/tagout.