Violation Detail
Standard Cited: 19100333 B02 III Selection and use of work practices
Inspection Nr: 1369912.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,260.00
Current Penalty: $0.00
Issuance Date: 06/10/2019
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 07/05/2019
Gravity: 10
Report ID: 0111500
Contest Date:
Final Order: 07/10/2019
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/10/2019 | $0.00 | 07/05/2019 | Serious | |
Penalty | Z: Issued | 06/10/2019 | $13,260.00 | 07/05/2019 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.333(b)(2)(iii): A lock and a tag was not placed on each disconnecting means used to de-energize circuits and equipment on which work was to be performed, except as provided in paragraphs (b)(2)(iii)(C) and (b)(2)(iii)(E) of this section: ESTABLISHMENT: The employer did not ensure through maintaining specific instructions and/or visual observation that a lock and a tag was placed on disconnecting means of the BB1 machine prior to allowing employees to manually assemble a prototype machine to install a power distribution box into the machine. On or about 12/14/2018, an employee inserting a power distribution box unevenly came in contact with the backwall resulting in a short circuit and an employee sustaining an electrical shock.