Violation Detail
Standard Cited: 19100147 D06 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1294192.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/09/2018
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 08/13/2018
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 08/03/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/03/2018 | $0.00 | 08/13/2018 | Serious | |
Penalty | Z: Issued | 07/09/2018 | $0.00 | 08/13/2018 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and de-energization of the machine or equipment had been accomplished: On or about February 19, 2018, the employer failed to ensure that verification that all possible energy sources on the M964, L12 Hydraulic Cutoff Machine were locked out prior to allowing employees to perform a die change out on the machine. The pneumatic energy source was not locked out at the time of the die change out.