Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1283359.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/22/2018
Nr Instances: 1
Nr Exposed: 50
Abatement Date: 04/12/2018
Gravity: 5
Report ID: 0111400
Contest Date:
Final Order: 04/12/2018
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/12/2018 | $0.00 | 04/12/2018 | Serious | |
Penalty | Z: Issued | 03/22/2018 | $0.00 | 04/12/2018 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: Location: Production Room No certification of inspection of the facility's LOTO program existed for any period prior to OSHA opening the inspection at the facility on December 18, 2017. The company's January 8, 2018 LOTO Program evaluation did not include the machines or equipment inspected or the employees included.