Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1222353.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/04/2017
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 5
Report ID: 0214200
Contest Date:
Final Order: 10/26/2017
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/26/2017 | $0.00 | Serious | ||
Penalty | Z: Issued | 10/04/2017 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a) Painting department The employer did not provide an annual fit test for a spray painter required to wear a full face air purifying respirator with combination cartridges while spray painting pieces. Paint products included, but were not limited to International Tru-glaze 4508H epoxy (ethylbenzene, methyl isobutyl ketone, xylene) and Research Solutions lacquer thinner (toluene, xylene, methanol, butyl acetate, acetone). Violation occurred on or about 4/4/17.