Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1217360.015
Citation: 01001C
Citation Type: Serious
Abatement Date: 06/22/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/12/2017
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 5
Report ID: 0522500
Contest Date:
Final Order: 07/06/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/06/2017 | $0.00 | 06/22/2017 | Serious | |
Penalty | Z: Issued | 06/12/2017 | $0.00 | 06/22/2017 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: a. Located in the USDA Packing Room at the workplace: The energy control procedure developed for the Rollstock machine failed to include specific procedural steps for shutting down and isolating the hazardous energy sources, specific steps for the placement of lockout devices, and specific steps to test the machine to determine and verify the effectiveness of the energy control measures.