Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 1211861.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/16/2017
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 09/29/2017
Gravity: 5
Report ID: 0214200
Contest Date: 09/08/2017
Final Order: 03/08/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/08/2018 | $0.00 | 09/29/2017 | Serious | |
Penalty | C: Contested | 10/13/2017 | $0.00 | 09/29/2017 | Serious | |
Penalty | Z: Issued | 08/16/2017 | $0.00 | 09/29/2017 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.134(f)(2): Employees using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) was used, and at least annually thereafter: a) Facility Employees using respirators such as, but not limited to, 3M 8511 filtering facepiece respirators and 3M 6200 half mask, negative pressure respirators, were not provided a fit test prior to initial use during powder coating powder production. Violation occurred on or about 02/21/2017.