Violation Detail
Standard Cited: 19100179 J02 Overhead and gantry cranes.
Inspection Nr: 1203128.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/22/2017
Nr Instances: 1
Nr Exposed: 30
Abatement Date: 08/07/2017
Gravity: 5
Report ID: 0317900
Contest Date:
Final Order: 07/25/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/25/2017 | $0.00 | 08/07/2017 | Serious | |
Penalty | Z: Issued | 06/22/2017 | $0.00 | 07/03/2017 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.179(j)(2): Frequent inspection. Items listed in this section were not inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections: a) Fabrication shop and storage/loading yard - On or about January 19, 2017, The employer had not implemented and enforced a policy to ensure frequent inspections were being made on the overhead cranes and had not ensured deficiencies were examined and determination made as to whether they constitute a safety hazard.