Violation Detail
Standard Cited: 19100147 E01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1197782.015
Citation: 01001C
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/06/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 5
Report ID: 0317900
Contest Date:
Final Order: 05/02/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/02/2017 | $0.00 | Serious | ||
Penalty | Z: Issued | 04/06/2017 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(e)(1): Before lockout tagout devices were removed, the work area was not inspected to ensure that nonessential items had been removed or ensured that machine or equipment components were operationally intact. a) Palram 2000, Inc., P3 - On or about December 1, 2016, after knife blade changing operations were completed on the Bryer Extrusion Lines brand D-78224 cross cutting saw the machine knife carriage metal mesh guards were not replaced prior to re-starting the machine.