Violation Detail
Standard Cited: 19100147 D05 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1022119.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $0.00
Issuance Date: 07/13/2015
Nr Instances: 4
Nr Exposed: 19
Abatement Date: 06/16/2016
Gravity: 10
Report ID: 0522500
Contest Date: 07/29/2015
Final Order: 05/16/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/16/2016 | $0.00 | 06/16/2016 | Serious | |
Penalty | C: Contested | 08/04/2015 | $7,000.00 | 08/15/2015 | Serious | |
Penalty | Z: Issued | 07/13/2015 | $7,000.00 | 08/15/2015 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.147(d)(5)(i): Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy shall be relieved, disconnected, restrained, and otherwise rendered safe. a. During the lockout of hydraulic press HSP-001, the gravitational energy is not relieved, disconnected, restrained, or otherwise rendered safe. b. During the lockout of hydraulic press HSP-002, the gravitational energy is not relieved, disconnected, restrained, or otherwise rendered safe. c. During the lockout of hydraulic press HSP-003, the gravitational energy is not relieved, disconnected, restrained, or otherwise rendered safe. d. During the lockout of hydraulic press HSP-004, the gravitational energy is not relieved, disconnected, restrained, or otherwise rendered safe.