Violation Detail
Standard Cited: 19261053 B05 I Ladders.
Inspection Nr: 992409.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $6,600.00
Current Penalty: $0.00
Issuance Date: 02/25/2015
Nr Instances: 1
Nr Exposed: 6
Abatement Date:
Gravity: 5
Report ID: 0419700
Contest Date: 03/18/2015
Final Order: 02/18/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/18/2016 | $0.00 | Serious | ||
Penalty | C: Contested | 03/19/2015 | $6,600.00 | Serious | ||
Penalty | Z: Issued | 02/25/2015 | $6,600.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a. On or about August 28, 2014, On the front of the building, the 24-foot extension ladder being used to access the roof had a working length of 10.8 feet, and the horizontal distance from the top support to the foot of the ladder was 6 feet.