Violation Detail
Standard Cited: 19260451 B06 General requirements.
Inspection Nr: 92534.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/23/2011
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 09/01/2011
Gravity: 10
Report ID: 0522500
Contest Date:
Final Order: 09/21/2011
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/21/2011 | $0.00 | 09/01/2011 | Serious | |
| Penalty | Z: Issued | 08/23/2011 | $0.00 | 09/01/2011 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1926.451(b)(6): \\\\r\\\\n\\\\r\\\\nOn scaffolds where scaffold planks are abutted to create a long platform, each abutted end shallrest on a separate support surface. This provision does not preclude the use of common support members, such as \\\\\\\"T\\\\\\\" sections, to support abuttingplanks, or hook on platforms designed to rest on common supports.\\r\\n\\r\\nAt the worksite, the planks on a system scaffold approximately 150 feet in height overlapped one over the other which did not provide each abutting plank separate support.
Translate