Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 921068.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/23/2013
Nr Instances: 1
Nr Exposed: 20
Abatement Date: 11/07/2013
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 10/30/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/30/2013 | $0.00 | 11/07/2013 | Serious | |
| Penalty | Z: Issued | 09/23/2013 | $0.00 | 11/07/2013 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): a) On or about July 18, 2013, the employer did not assure the blow molding machines were properly de-energized when performing servicing and maintenance. An employee was exposed to crushing and amputation hazards on blow mold machine number 12 while using a push button as an energy isolating device.