Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 905368.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 10/04/2013 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/19/2013
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0111500
Contest Date:
Final Order: 09/13/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/13/2013 | $0.00 | 10/04/2013 | Serious | |
Penalty | Z: Issued | 08/19/2013 | $0.00 | 10/04/2013 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.134(f)(2): The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter. WORKSHOP: The employee, required to wear the halfface piece cartridge type respirator during the tasks, such as (but not limited to) pad painting had not been fit tested.